-
27
Dose and spatial resolution analysis of grating-based phase-contrast mammography using an inverse Compton x-ray source. Journal of Medical Imaging 7 (2), 2020, 023505-1 - 023505-13 mehr… BibTeX Volltext ( DOI ) -
26
A proof of principle experiment for microbeam radiation therapy at the Munich compact light source. Radiation and Environmental Biophysics 59, 2020, 111–120 mehr… BibTeX Volltext ( DOI ) -
25
K-edge subtraction imaging for iodine and calcium separation at a compact synchrotron x-ray source. Journal of Medical Imaging 7 (2), 2020, 023504 mehr… BibTeX Volltext ( DOI ) -
24
K-edge Subtraction Computed Tomography with a Compact Synchrotron X-ray Source. Scientific Reports 9 (1), 2019, 13332 mehr… BibTeX Volltext ( DOI ) -
23
Contrast-enhanced spectral mammography with a compact synchrotron source. PLOS One 14 (10), 2019, e0222816 mehr… BibTeX Volltext ( DOI ) -
22
Evaluation and optimization of multimodal x-ray imaging techniques for inverse Compton x-ray sources. Advances in Laboratory-based X-Ray Sources, Optics, and Applications VII, SPIE, 2019 mehr… BibTeX Volltext ( DOI ) -
21
Visualizing treatment delivery and deposition in mouse lungs using in vivo x-ray imaging. Journal of Controlled Release 307, 2019, 282-291 mehr… BibTeX Volltext ( DOI ) -
20
Propagation-based phase-contrast x-ray tomography of cochlea using a compact synchrotron source. Scientific Reports 8 (1), 2018, 4922 mehr… BibTeX Volltext ( DOI ) -
19
In vivo Dynamic Phase-Contrast X-ray Imaging using a Compact Light Source. Scientific Reports 8 (1), 2018, 6788 mehr… BibTeX Volltext ( DOI ) -
18
Dose-compatible grating-based phase-contrast mammography on mastectomy specimens using a compact synchrotron source. Scientific Reports 8 (1), 2018, 15700 mehr… BibTeX Volltext ( DOI )
PD Dr.-Ing. habil. Bernhard Gleich
Technical University of Munich
Munich Institute of Biomedical Engineering (MIBE)
Postal address
Postal:
Boltzmannstr. 11
85748 Garching b. München
Place of employment
Munich Institute of Biomedical Engineering (MIBE)
Work:
Boltzmannstr. 11(5701)/I
85748 Garching b. München
- Phone: +49 (89) 289 - 10815
- Room: 5701.01.204
- gleich@tum.de
- X-ray Tensor Tomography
- Setup and maintenance of a directional dark-field imaging beamline at the MuCLS
- Applications of grating interferometry in medicine and material science
- Development of low field NMR devices
- High frequency transcranial magnetic stimulation
Winter term 2023/24
Course no. | Title | Lecturer (assistant) |
---|---|---|
0000003133 | BEMP Lab 05: Measurement and Filtering of Bioelectrical Signals |
|
000EI71045 | Design of Safe Medical Devices and Boards |
|
0000002587 | Practical Course development of bio-signal amplifiers |
|
0000004491 | Project Week Medical Technology Prototype |
|
Summer term 2024
Course no. | Title | Lecturer (assistant) |
---|---|---|
0000000398 | Biostatistics | |
0000001079 | Exercise to Biostatistics | |
0000002730 | Practical Course development of bio-signal amplifiers |
|